Silencer assemblies (Fig. 1) are used as non-adjustable throttling elements of desuperheating stations (DS) and pressure-reducing desuperheating stations (PRDS). They are intended to reduce noise levels during steam throttling and expansion in the DS and PRDS. They are installed right after the throttling valves of the DS or PRDS.

Silencers with a throttling-cooling grate (Fig. 2) are intended to cool steam and are an integral part of the kit included in DS and PRDS.

End connection – butt-welded.

Installation position: horizontal or vertical.

Flow direction: follow the arrow on the body.

Climatic version: N3 acc.to GOST 15150-69.

Техническая характеристика и основные размеры

Обозначение

маркировочное

DN Параметры

среды

Массовый расход среды (на выходе),

G, т/ч

F1 , cм 2 Материал корпуса L,

мм

L1 ,

мм

H,

мм

Масса, кг Рисунок
Р ВХ /t ВХ ?,

МПа/ ?С

Р ВЫХ /t ВЫХ ?,

МПа/ ?С

Ш.200.012/006 050.004 200 12/435 6/220 50 110,0 20 200 42 139,5 14,8 2
Ш.200.019/012 050.003 200 19/435 12/435 50 45,4 20 205 12 1
Ш.300.003/002,5 050.006 300 3/220 2,5/160 35 226,7 20 305 52,5 212,5 29,7 2
Ш.300.003/003 050.005 300 3,3/220 3/220 35 196,3 20 300 20,5 1